Instructions for use: CM Loc Flex implants 

Martin Schimmel presents a case demonstrating the clinical application of the CM Loc Flex implant A female 67-year-old patient with an edentulous upper jaw was selected for this clinical procedure. She had received four Straumann Standard Implants (SLA active surface, 8mm length, regular neck, 4.1mm diameter, Straumann, Switzerland) in March 2011. Figure 1 (main picture above): Clinical scenario with malaligned implants and Locator attachments; the implant UL2 was already lost. The attachment showed severe signs of wear and needed to be replaced The implants has been placed following the recommended surgical protocol for edentulous patients in the maxilla without augmentation procedures, but due to insufficient local alveolar bone mass they had been placed in an unfavourable angle for the subsequent prosthetic restoration. Figure 2: Unfavourable position of the secondary